Product Number: 330104-00-10-20-12-05
Reliability: Engineered for high reliability in critical environments
System Control: Enables operations such as start
High-Level Current Input: Supports standard 4–20 mA signals from industrial transmitters
Drift due to Ambient Temperature Change: ±16 µA/10 ˚C
Emerson Epro CON011/916-120 Eddy Current Signal Converter Analog Digital Module Product Number: 330104-00-10-20-12-05Description This CON011 916 120 signal converter processes signals from eddy current sensors, enabling precise monitoring of radial and axial shaft displacement, position, eccentricity, and speed. It is widely used in applications such as steam turbines, gas turbines, compressors, pumps, and fans. Specifications Input Sensor Types: Compatible with PR6422, PR6423, PR6424, PR6425, and PR6426 sensors. Frequency Range: 0 to 20,000 Hz ( 3 dB). Output